Abstract:
In this study it has been aimed that a little amount of the electricity energy need of Celal Bayar
Universty Golmarmara Vocational high school in the city Manisa will be covered by the wind tribunes
with the little power.
In this study, the electricity energy amounts, which will be produced by the wind tribunes of 2kW,
3kW and 5kW has been kept as aim. To be able to determine the energy amounts from these tribunes,
the wind speed and direction data of 8260 hours for 1 year has been provided from the meteorology
station. These data of 8760 hours for a year has been registered making use of Excel computer
program. The quivalent of these wind speeds of 8760 hours measured at 10 metres height coinciding at
the altitude of 20m and 30m have also been accounted at excell computer program using Hellman‘s
Relation. The theoretical power, net power and electricity energy values of each hour to be produced
from the 2kW, 3kW and 5kW’ wind tribunes for the altitudes of 10m, 20m and 30 metres have been
accounted one by one.
At the end of the study, it has been concluded that the basic needs such as the enlightening and
computer of the Vocational high school can easily be obtained from a wind tribune with little power.